Fn7-12D/630-20 Indoor Use Load Switch with Good Price
Basic Info
Model No.: FN7-12D/630-20
Product Description
Model NO.: FN7-12D/630-20 Application: 3 Phase AC Power Stystem Certification: ISO9001,SGS, Ce Environment: Indoor High Voltage Origin: Jiangyin Yunfeng, China Type: Gas-Production High Voltage Arc-Extinguishing Principle: Arc Quenching Principle Test Equipment: IEC Standard Trademark: YF Product Overview
YFN7(FN7)-12 series indoor AC HV load switch is a gas-production HV load switch and Fuse combination unit with arc quenching principle.It is applied in three-phase AC 50Hz power system with rated voltage 12kV for breaking the load current and making the short-circuit current.The fuse combination unit can break the short-circuit current and has the function of single-phase fuse three-phase tripping and breaking.It is the ideal selection for protecting the line, equipment and Transformer. Its performance meets the requirements of national standards GB 3804-2004 High-voltage alternating-current switches for rated voltage above 3.6kV and less than 40.5kV and GB 16926-2009 High-voltage alternating current switch-fuse combinations.
Model Specification
Indoor AC HV load switch
Note: The sensor with live display can be used for the switch insulator
Characteristics:
---small size
---light weight
---simple & reasonable structure
---small operating force
---reliable performance & convenient maintenance
Service Conditions
1.Altitude≤1000m;
2.Ambient temperature-25ºC-+ 40ºC;
3.The daily average of relative humidity shall not be larger than 95% and the monthly average shall not be larger than 90%:
4.The ambient air shall not be subject to the obvious pollution such as corrosive or combustible gas and steam;
5.The site without fire hazards and explosion hazards;
6.The site that the seismic intensity does not exceed degree 8; the gradient shall not exceed 5°
Main Technical Parameters
Contact us if you need more details on load break switch. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Switchgear、Switch Cabinet. If these products fail to match your need, please contact us and we would like to provide relevant information.
YFN7(FN7)-12 series indoor AC HV load switch is a gas-production HV load switch and Fuse combination unit with arc quenching principle.It is applied in three-phase AC 50Hz power system with rated voltage 12kV for breaking the load current and making the short-circuit current.The fuse combination unit can break the short-circuit current and has the function of single-phase fuse three-phase tripping and breaking.It is the ideal selection for protecting the line, equipment and Transformer. Its performance meets the requirements of national standards GB 3804-2004 High-voltage alternating-current switches for rated voltage above 3.6kV and less than 40.5kV and GB 16926-2009 High-voltage alternating current switch-fuse combinations.
Model Specification
Indoor AC HV load switch
Note: The sensor with live display can be used for the switch insulator
Characteristics:
---small size
---light weight
---simple & reasonable structure
---small operating force
---reliable performance & convenient maintenance
Service Conditions
1.Altitude≤1000m;
2.Ambient temperature-25ºC-+ 40ºC;
3.The daily average of relative humidity shall not be larger than 95% and the monthly average shall not be larger than 90%:
4.The ambient air shall not be subject to the obvious pollution such as corrosive or combustible gas and steam;
5.The site without fire hazards and explosion hazards;
6.The site that the seismic intensity does not exceed degree 8; the gradient shall not exceed 5°
Main Technical Parameters
Serial No. | Item | Unit | YFN7-12 HV Load Switch |
1 | Rated voltage | kV | 12 |
2 | Rated frequency | HZ | 50 |
3 | Rated current | A | 630 |
4 | Rated short-circuit breaking current of fuse | kA | --- |
5 | Rated breaking transfer current | A | --- |
6 | Main loop resistance | μΩ | ≤80 |
7 | Rated active load breaking current | A | 630 |
8 | Rated short-time withstand current(thermal stability current)/duration | kA/s | 20/4 |
9 | Rated short-time withstand current(thermal stability current)/duration of Earthing switch | kA/s | 16/2 |
10 | Rated peak withstand current(dynamic current) | kA | 50 |
11 | 1 min power-frequency withstand voltage(effective value)to earth,phase-to-phase/isolating fracture | kV/kV | 42/48 |
12 | Full-wave lightning impluse withstand voltage(peak) to earth,phase-to-phase/isolating fracture | kV/kV | 75/85 |
13 | Mechanical life | Time | 2000 |
14 | Rated opening operation voltage | V | --- |
15 | Time of switch opening triggered by breaking of fuse | ms | --- |
Contact us if you need more details on load break switch. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Switchgear、Switch Cabinet. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : 12kV Indoor HV load switch
Other Products
Hot Products
YFZRN-24 AC Hv Vacuum Load Switch with Safe and Easy FuseFn5-12r (T) D Indoor AC Hv Load Switch-Fuse Combination Unitout Door Load Switch for ABB CabinetOrignal Hot Sale out Door Isolating Switch for 1250Aout Door Three Position Spring Load SwitchHot Sale out Door Circuit Breaker for Oumaout Door Circuit Breaker Mechanism for High Pressure CabinetParts of Electrical Control Panel Low Voltage Switchgear11kV Parts of Vacuum Circuit Breaker8PT CrankKEMA Testified Medium Voltage Switchgear Epoxy Resin SensorIndustrial Control Panel Genset Control Panel Electrical SwitchgearWecome Group Power Distribution Equipment Series Type SF6 Ring Main UnitMNS Control Cubicle Switch CabinetKYN28 24kV Metal Enclosed Medium Voltage Withdrawable Switchgear PanelMedium Voltage VS1 Indoor 11kV Vacuum Circuit Breaker