High Quality Load Break Switch, Sf6 Load Break Switch, Indoor Load Break Switch Suppliers in China

Home > Products > Load break switch > SF6 load break switch > Sf6 Load break switch for indoor switchgear

Sf6 Load break switch for indoor switchgear

Product Description

Liyond

Sf6 Load break switch for indoor switchgear 

Product display

Sf6 Load break switch for indoor switchgear 

 
Sf6 Load break switch for indoor switchgear
 
Summary

FLN⟩ -24kV SF6 load break switch is a switch equipment for medium voltage Switchgear,  using SF6 gas as arc extinguishing and insulating medium. There are three working positions:open, closed, earth position in the switch.  The compact size,  easy installation,  and fine adaptability to environment make the switch suitable for many different applications.

It can be divided into two types: FLN⟩-24kV ( K type single spring operating mechanism ), FLRN⟩ -24kV(A type double spring operating mechanism).  The latter type could be equipped with Fuse combination,  having control and protecting function,  which can be used for power supply and substation as a protecting and control device,  especially suitable for ring main unit,  cable distribution box and switching substation.

Technical specification

MAIN TECHNICAL SPECIFICATION UNIT FLN ⟩ -24D/T630-20 Load break switch FLRN ⟩ -24D/T100-31.5 LBS + Fuse-combination units
Rated voltage KV 24 24
Rated frequency Hz 50 50
Rated current A 630 100
Short-duration(1minpower frequency withstand voltage KV 65 65
Lightning impulse withstand voltage KV 125 125
Rated power frequency withstand voltage(5min) KV 24  24
Rated short-time withstand current(Load break switch/3s)  KA  20  20
Rated short-time withstand current(Earthing switch/2s)  KA  20  20
Rated peak withstand current(Load break switch)  KA  50  50
Rated peak withstand current(Earthing switch)  KA  50  50
Rated short-circuit making current(Load break switch)  KA  50  125
Rated short-circuit making current(Earthing switch)  KA  50  50
Rated closed-loop dropout current  A  630  
Rated active load breaking current  A  630  
Rated cable-charging breaking current  A  10  10
Rated short-circuit breaking current  KA    31.5
Rated transfer current  A    1400
Fuse type      XRNT-12KV/100A
Fuse impact output energy  J    1±0.5
Mechanical endurance LBS/Earthing switch  Time  3000/2000  3000
Air insulation distance of charged body and ground  mm  ≥180  ≥180
SF6 Gas pressure(Relative pressure at 20℃  bar 0.4 0.4
Opening and Closing simultaneity ms ≤2 ≤2

 

4K

Hot products

Company profile

Sf6 Load break switch for indoor switchgear

Sf6 Load break switch for indoor switchgear

Sf6 Load break switch for indoor switchgear 

Certifications

Sf6 Load break switch for indoor switchgear 

Package&transport
Sf6 Load break switch for indoor switchgear 

V Sf6 load break switch

 

 

 

 

Contact us if you need more details on Load break switch. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Sf6 Load Break SwitchIndoor load break switch. If these products fail to match your need, please contact us and we would like to provide relevant information.